RobStride / Python_Sample

7 2 0 更新于 2026-06-04 18:18

Robstride Dynamics Python SDK

Python API for the RobStride series of integrated CAN servo motors (RS-00 ~ RS-06). The SDK speaks the manufacturer's private CAN protocol over a Linux SocketCAN interface and exposes a small, idiomatic Python class (RobstrideBus) for reading parameters, writing parameters, and controlling motors in any of the four supported run modes.

Features

  • Full coverage of the four control modes documented in the RS01 manual:
    • Operation control mode (MIT, run_mode = 0) — single-frame impedance control with feed-forward velocity / torque.
    • Position mode (PP) (run_mode = 1) — profile position with vel_max / acc_set / loc_ref.
    • Position mode (CSP) (run_mode = 5) — cyclic synchronous position with limit_spd / loc_ref.
    • Velocity mode (run_mode = 2) — limit_cur / acc_rad / spd_ref.
    • Current mode (run_mode = 3) — direct iq_ref.
  • Bus-level conveniences: enable, disable, set_run_mode, parameter read / write, ping_by_id, scan_channel, read_id, write_id.
  • Optional per-motor calibration (direction, homing_offset) is applied consistently across operation, position, velocity, and current control helpers, so user-frame setpoints are decoupled from raw motor frame.
  • Detailed status / fault decoding from the type-2 feedback frame (uncalibrated, stall, encoder fault, over-temperature, over-current, under-voltage…).

Installing

From PyPI

pip install robstride-dynamics

From source (editable)

git clone https://github.com/ROBSTRIDE-DYNAMICS/Robstride-Dynamics-Python-SDK.gitcd Robstride-Dynamics-Python-SDKpip install -e .

The SDK requires Python ≥ 3.10 and depends only on numpy, python-can, and tqdm.

Hardware setup

  1. Wire the motor's CAN bus to a SocketCAN-compatible adapter (e.g. the official RobStride USB-CAN module). Make sure the 120 Ω terminator is enabled on at least one end of the bus.
  2. Bring up the CAN interface on Linux at the motor's baud rate (1 Mbps by default):
    sudo ip link set can0 up type can bitrate 1000000
  3. Power the motor and confirm the controller LED is steady.
  4. (Optional) Sniff the bus to confirm wiring:
    candump can0

If you do not know the motor's CAN id, use RobstrideBus.scan_channel:

from robstride_dynamics import RobstrideBus print(RobstrideBus.scan_channel("can0"))# {1: [1, <uuid>]}

Quick start

from robstride_dynamics import Motor, ParameterType, RobstrideBus bus = RobstrideBus(    channel="can0",    motors={"joint_1": Motor(id=0x01, model="rs-01")},)bus.connect() try:    # Read a parameter (e.g. mechanical position in rad)    pos = bus.read("joint_1", ParameterType.MECHANICAL_POSITION)    print(f"current position: {pos:+.3f} rad")     # Switch to operation control mode and enable torque    bus.disable("joint_1")    bus.set_run_mode("joint_1", 0)    bus.enable("joint_1")     # Send one MIT control frame (hold current position with light impedance)    bus.write_operation_frame(        motor="joint_1",        position=pos,        kp=10.0, kd=1.0,        velocity=0.0, torque=0.0,    )    print(bus.read_operation_frame("joint_1")) finally:    bus.disable("joint_1")    bus.disconnect(disable_torque=False)

Examples

The examples/ folder contains one runnable script per control mode. All scripts share the same constants block (CHANNEL, MOTOR_NAME, MOTOR_ID, MOTOR_MODEL) at the top, edit those to match your hardware before running.

ScriptModerun_modeWhat it does
examples/operation_control.pyOperation control (MIT)0Tracks a sinusoidal position reference at 200 Hz using write_operation_frame with feed-forward velocity.
examples/position_control.pyPosition (PP) + (CSP)1, 5Walks through a few PP waypoints with a trapezoidal profile, then streams a CSP sinusoid at 100 Hz.
examples/velocity_control.pyVelocity2Steps through a list of target velocities, holding each for a fixed time and printing actual v / iq.
examples/current_control.pyCurrent3Steps through a small ±Iq profile, printing actual v / iq / tau. Use a free or safely-loaded shaft.

Run any example with:

python examples/operation_control.py

Each script follows the same safety pattern:

disable -> set_run_mode -> enable -> control loop -> write zero setpoint -> disable -> disconnect

API overview

Bus lifecycle

  • RobstrideBus(channel, motors, calibration=None, bitrate=1_000_000)
  • bus.connect(), bus.disconnect(disable_torque=True)
  • bus.is_connected, bus.scan_channel(channel), bus.ping_by_id(id)

Per-motor state

  • bus.enable(motor), bus.disable(motor)
  • bus.set_run_mode(motor, run_mode) — 0 MIT, 1 PP, 2 velocity, 3 current, 5 CSP
  • bus.read_id(motor), bus.write_id(motor, new_id)

Parameter I/O

  • bus.read(motor, ParameterType.X) → value
  • bus.write(motor, ParameterType.X, value)

ParameterType exposes every documented index (e.g. MODE, MECHANICAL_POSITION, MECHANICAL_VELOCITY, IQ_FILTERED, POSITION_TARGET, VELOCITY_TARGET, IQ_TARGET, PP_VELOCITY_MAX, PP_ACCELERATION_TARGET, VELOCITY_LIMIT, CURRENT_LIMIT, …).

Control helpers

MethodMode
write_operation_frame(motor, position, kp, kd, velocity=0, torque=0)Operation control (MIT)
read_operation_frame(motor) → (pos, vel, torque, temp)Operation control (MIT)
move_to_position_pp(motor, position, velocity_max=None, acceleration=None)PP
move_to_position_csp(motor, position, velocity_limit=None)CSP
set_target_velocity(motor, velocity, acceleration=None, current_limit=None)Velocity
set_target_current(motor, iq)Current

All *_position* / *_velocity / *_current helpers respect the optional calibration dict and convert from user frame to motor frame internally.

Calibration (optional)

RobstrideBus accepts a calibration dict so user-frame setpoints can be expressed regardless of how the motor is mounted:

calibration = {    "joint_1": {        "direction": -1,        # flip rotation        "homing_offset": 1.5,   # rad subtracted from user position    },} bus = RobstrideBus(    channel="can0",    motors={"joint_1": Motor(id=0x01, model="rs-01")},    calibration=calibration,)

When calibration is provided, all control helpers automatically apply raw = user * direction + homing_offset on the way out and the inverse on the way back, so the application code only ever sees user-frame values.

Safety notes

  • Always run disable (or rely on disconnect(disable_torque=True)) before exiting your script. Both are idempotent.
  • Mode switches must happen with the motor disabled. The example scripts and helper methods follow this rule; if you mix raw bus.write() calls with control helpers, do the same.
  • In current mode there is no velocity feedback loop — even small Iq values will accelerate a free shaft very quickly. Always start small and write iq=0 before disabling.
  • If you observe WARNING: Received no response from the motor, check the CAN id, baud rate, terminator, and 24 V/36 V/48 V supply. The motor only sends type-2 feedback frames in response to host commands unless active reporting (type 24) has been enabled.

Documentation references

The protocol implementation follows the RobStride RS01 user manual. Key sections:

  • §3.4 — Upper-computer demos for each control mode.
  • §4.1 — Private communication protocol (frame layout for types 0/1/2/3/4/ 17/18/21/22/23/24/25).
  • §4.3 — Per-mode workflow (operation control, current, velocity, position CSP, position PP, stop).
  • §4.4 — C reference snippets for enable / operation control / stop / parameter write.

License

MIT — see LICENSE.